ABB’s softstarter is an electrical device connected between the main power and the motor. The softstarters increase a motor’s lifetime by protecting it from electrical stresses. With many built-in motor protection features, your motor is safe in its hands. The softstarter is also easy to learn and set-up.
ABB Soft Starter
The PSTX offers complete motor protection and is able to handle both load and network irregularities. PT-100, earth fault protection and over/under voltage protection along with many other functions keep your motor safer than ever.
Current 30A… 1250A (inside-delta: 2160A)
Main voltage 208V… 600V, 208V… 690V
Rated control supply voltage 100… 250V AC, 50/60 Hz
Frame sizes A, B, C, D, E, F
Electrical sizes 19
Communication protocols Modbus RTU, Profibus, Profinet, Ethercat, BACnet, Ethernet, DeviceNet, Anybus
Certifications CE, cULus, CCC, EAC, ANCE. C-tick, KC
Approvals ABS, DNV, Lloyd’s register, CCS, PRS, Class NK
Related products
-
ABB Sace Formula
DESCRIPTION
Formula Al
- 15A-125A, lP – 3P, 230/440VAC
Formula A2
- 125A- 240A, 2P – 3~ 230/480VAC
Formula A3
- 320A- 630A, 3P, 230/480VAC
TmaxSeries
- 250A-1600A, 3P, 690VAC
Benefits
The SACE FORMULA circuit-breakers from 15A to 630A consist of the interruption part together
with the trip unit and they can be installed:- directly on the back plate of the cubicles.
- on a DIN rail (A1 and A2).
- back door (A1, A2 and A3, 2-3 4 poles).
ABB’s SACE® FORMULA™ molded case circuit breaker line offers simplicity and quality in some of the smallest dimensions available.
Technical Specs
IEC 60947-2
- fixed version;
- polarity: 1 pole (A1 and A2), 2 poles (A1 and A2), 3 poles (A1, A2 and A3), 4 poles (A1, A2 and A3);
- maximum breaking capacity of 36kA for A1 and A2 and of 50kA for A3 at 415V AC;
- fixed thermomagnetic trip unit (TMF) for protection of networks in alternating and direct current (A1, A2, A3);
- ELT LI electronic trip unit with fixed thresholds for the protection of networks in alternating current (A3);
- only two depths: 60mm (A1, A2) and 103.5mm (A3);
- standard front terminals;
- the possibility of use at 50°C without derating up to 250A (except for A1 125A);
- a special version for A3 300A-400A for use at 50°C.”
Features
- Ready to use
- Fixed thresholds on trip units, pre-cabled version of accessories and FORMULA link save time putting FORMULA in service.
- Easy to order and to use
- 1,2,3, and 4 poles versions up to 250A, no derating up to 50°C and common range of click-in accessories
- Compact and competitive
- Extremely compact dimensions and coordinated depths mean standardized dimensions and savings in distribution board design.
Certifications
SACE FORMULA DSA circuit-breakers and accessories are designed, manufactured and tested in conformity with:
- IEC 60947-2 standard;
- EC “Low Voltage Directive” (LVD) N° 2006/95/EC
- EC “Electromagnetic Compatibility Directive” (EMC) 2004/108/CE
Standards:
- ISO 9001 international Standard;
- EN ISO 9001 (equivalent) European Standards;
- UNI EN ISO 9001 (equivalent) Italian Standards;
- IRIS International Railway Industry Standard.
ABB Quality System obtained its first certification with RINA certification body in 1990.
Attention to protection of the environment is a priority for ABB. Confirmation of this is an Environmental Management System certified by RINA in conformity with the InternationalISO14001 Standard. In 1999, the Environmental Management System was integrated with the Occupational Health and Safety Management System according to the OHSAS 18001 Standard and later, in 2005, with the SA 8000 (Social Accountability 8000) Standard, committing itself to respect of business ethics and working conditions.
Categories: ABB, Circuit Protection & Motor Controls -
LIGHTNING STRIKE COUNTER ABB
LIGHTNING STRIKE COUNTER ABB
2CTH060001R0000
To protect the systems against the transient overvoltage (lightning)
Equipotential bonding
Categories: ABB, Lightning Protection -
SACE Tmax XT
DESCRIPTION
The SACE Tmax XT series of Moulded Case Circuit Breakers (MCCBs) are designed to maximize ease of use, integration and connectivity while reliably delivering safety and quality. Rather than just offering standalone protection, they are seen as key elements of the system that give you complete flexibility, extreme breaking capabilities and reliable performance under pressure. With seven different sizes and protection features of up to 1600A there’s a solution for every purpose.
Tmax XT moulded case circuit breakers guarantee an extremely high performance level while being progressively smaller in size, simple to install and able to provide increasingly better safety. Range is complete with four frame sizes: XT1, XT2 up to 160A and XT3, XT4 up to 250A.
FEATURES
- High breaking capacity in compact dimensions
- XTraordinary limiting characteristics allow savings in copper and footprint in switchboard, high selectivity values and very compact motor protection solutions.
- Ease of use and installation flexibility
- A dedicated range of accessories and a renewed solution for electronic trip units to adapt Tmax XT to different applications scenarios.
- Customized protection and information availability
- Specific electronic trip units for energy metering, motor protection and generator protection in addition to a Modbus communication module for integration in a supervision system.
- Increased safety for operators
- Wide range of keylocks and padlocking options, plug in and withdrawable versions to speed up maintenance operations and improved diagnostic to have ready to use information about breakers’ status.
Benefits
Cloud connected
To keep a system under control it should be monitorable from everywhere.Plant management of the future – SACE Tmax XT sets standards in modern plant and energy management. Access, monitor and control information remotely, anywhere, at any time. Improving efficiency and saving energy.
Tailor made
Even if the task is complex the solution is simple.Maximum flexibility for every application – SACE Tmax XT sets standards for electrical installations. Easy selection, one-fits-all accessories and intuitive design pave the way for smart manufacturing of panels and fast upgrades. Even for the most critical projects.
Outstanding technology
Meeting high-performance requirements with zero efforts.Continuity of service and equipment protection – SACE Tmax XT sets standards when extreme breaking capacity is needed. Sharing the same logics, interfaces and features regardless of operating voltage and environmental conditions. Embedding the most advanced protection into the smallest of frames.
Top-level products
The reliability of a system relies on the interplay of details.Absolute attention to detail, with style – from design to manufacturing, SACE Tmax XT sets standards for edge technologies. Almost a century of research and experience means top-level products that are ready to face future challenges.
Technical Specs
- IEC 60947-2
- 16A to 1600A
- 3P,4P
- Fixed, withdrawable
- Upto to 200kA Icu @415V
Categories: ABB, Circuit Protection & Motor Controls -
ABB Contact Block
CA5-40E is a 4-pole front mounted auxiliary contact block equipped with screw terminals. CA5-..E version offers terminal assortment matching the marking of 3-pole A serie contactors: A..-30-00, A..-40-00, A..-22-00. CA5-40E is available with 4 N.O. and 0 N.C. instantaneous contacts for standard industrial environments.
Categories: ABB, Motor Protection & Controls
Reviews
There are no reviews yet.