Contactor
DESCRIPTION
- 9A – 370A, 3P, 240-690V
- 1 NO, 230-240V
- 1N0-1NC, 230-240V
- IEC 60947-4-1
Contactors and contactor relays
To keep things running you need control
“Contactor relays for auxiliary circuit switching
ABB’s contactor relays offering features products of technological advancement as well as products with specific purposes. NF contactor relays allow use in all parts of the world and in all network conditions. The mini contactor relays range offer various contact combinations and specific connection possibilities. The AS contactor relays are efficient and allow you to optimize your equipment design.”
Related products
-
SACE Tmax XT
DESCRIPTION
The SACE Tmax XT series of Moulded Case Circuit Breakers (MCCBs) are designed to maximize ease of use, integration and connectivity while reliably delivering safety and quality. Rather than just offering standalone protection, they are seen as key elements of the system that give you complete flexibility, extreme breaking capabilities and reliable performance under pressure. With seven different sizes and protection features of up to 1600A there’s a solution for every purpose.
Tmax XT moulded case circuit breakers guarantee an extremely high performance level while being progressively smaller in size, simple to install and able to provide increasingly better safety. Range is complete with four frame sizes: XT1, XT2 up to 160A and XT3, XT4 up to 250A.
FEATURES
- High breaking capacity in compact dimensions
- XTraordinary limiting characteristics allow savings in copper and footprint in switchboard, high selectivity values and very compact motor protection solutions.
- Ease of use and installation flexibility
- A dedicated range of accessories and a renewed solution for electronic trip units to adapt Tmax XT to different applications scenarios.
- Customized protection and information availability
- Specific electronic trip units for energy metering, motor protection and generator protection in addition to a Modbus communication module for integration in a supervision system.
- Increased safety for operators
- Wide range of keylocks and padlocking options, plug in and withdrawable versions to speed up maintenance operations and improved diagnostic to have ready to use information about breakers’ status.
Benefits
Cloud connected
To keep a system under control it should be monitorable from everywhere.Plant management of the future – SACE Tmax XT sets standards in modern plant and energy management. Access, monitor and control information remotely, anywhere, at any time. Improving efficiency and saving energy.
Tailor made
Even if the task is complex the solution is simple.Maximum flexibility for every application – SACE Tmax XT sets standards for electrical installations. Easy selection, one-fits-all accessories and intuitive design pave the way for smart manufacturing of panels and fast upgrades. Even for the most critical projects.
Outstanding technology
Meeting high-performance requirements with zero efforts.Continuity of service and equipment protection – SACE Tmax XT sets standards when extreme breaking capacity is needed. Sharing the same logics, interfaces and features regardless of operating voltage and environmental conditions. Embedding the most advanced protection into the smallest of frames.
Top-level products
The reliability of a system relies on the interplay of details.Absolute attention to detail, with style – from design to manufacturing, SACE Tmax XT sets standards for edge technologies. Almost a century of research and experience means top-level products that are ready to face future challenges.
Technical Specs
- IEC 60947-2
- 16A to 1600A
- 3P,4P
- Fixed, withdrawable
- Upto to 200kA Icu @415V
Categories: ABB, Circuit Protection & Motor Controls -
Sace Formula
DESCRIPTION
Formula Al
- 15A-125A, lP – 3P, 230/440VAC
Formula A2
- 125A- 240A, 2P – 3~ 230/480VAC
Formula A3
- 320A- 630A, 3P, 230/480VAC
TmaxSeries
- 250A-1600A, 3P, 690VAC
Benefits
The SACE FORMULA circuit-breakers from 15A to 630A consist of the interruption part together
with the trip unit and they can be installed:- directly on the back plate of the cubicles.
- on a DIN rail (A1 and A2).
- back door (A1, A2 and A3, 2-3 4 poles).
ABB’s SACE® FORMULA™ molded case circuit breaker line offers simplicity and quality in some of the smallest dimensions available.
Technical Specs
IEC 60947-2
- fixed version;
- polarity: 1 pole (A1 and A2), 2 poles (A1 and A2), 3 poles (A1, A2 and A3), 4 poles (A1, A2 and A3);
- maximum breaking capacity of 36kA for A1 and A2 and of 50kA for A3 at 415V AC;
- fixed thermomagnetic trip unit (TMF) for protection of networks in alternating and direct current (A1, A2, A3);
- ELT LI electronic trip unit with fixed thresholds for the protection of networks in alternating current (A3);
- only two depths: 60mm (A1, A2) and 103.5mm (A3);
- standard front terminals;
- the possibility of use at 50°C without derating up to 250A (except for A1 125A);
- a special version for A3 300A-400A for use at 50°C.”
Features
- Ready to use
- Fixed thresholds on trip units, pre-cabled version of accessories and FORMULA link save time putting FORMULA in service.
- Easy to order and to use
- 1,2,3, and 4 poles versions up to 250A, no derating up to 50°C and common range of click-in accessories
- Compact and competitive
- Extremely compact dimensions and coordinated depths mean standardized dimensions and savings in distribution board design.
Certifications
SACE FORMULA DSA circuit-breakers and accessories are designed, manufactured and tested in conformity with:
- IEC 60947-2 standard;
- EC “Low Voltage Directive” (LVD) N° 2006/95/EC
- EC “Electromagnetic Compatibility Directive” (EMC) 2004/108/CE
Standards:
- ISO 9001 international Standard;
- EN ISO 9001 (equivalent) European Standards;
- UNI EN ISO 9001 (equivalent) Italian Standards;
- IRIS International Railway Industry Standard.
ABB Quality System obtained its first certification with RINA certification body in 1990.
Attention to protection of the environment is a priority for ABB. Confirmation of this is an Environmental Management System certified by RINA in conformity with the InternationalISO14001 Standard. In 1999, the Environmental Management System was integrated with the Occupational Health and Safety Management System according to the OHSAS 18001 Standard and later, in 2005, with the SA 8000 (Social Accountability 8000) Standard, committing itself to respect of business ethics and working conditions.
Categories: ABB, Circuit Protection & Motor Controls -
PSTX Soft Starter
DESCRIPTION
The PSTX combines many years of research and product development with extensive knowledge of application specific requirements and needs. The PSTX is our latest advancement in motor control and protection and adds new functionality with increased reliability to any motor starting application.
Benefits :
Complete Motor Protection
The PSTX offers complete motor protection and is able to handle both load and network irregularities. PT-100, earth fault protection and over/under voltage protection along with many other functions keep your motor safer than ever.
Reliable Operations
Time to use your processes to their full potential. The PSTX features many application enhancing features, including torque control, standstill brake, dynamic brake, motor heating, pump cleaning, underload, and lock rotor protections.
Flexible Communication
Bulit-in Modbus and as an option Anybus for all major communication protocols such as Modbus RTU, Profibus, Profinet, Ethercat, BACnet, Ethernet and DeviceNet.
Technical information :
Current : 30A… 1250A (inside-delta: 2160A)
Main voltage : 208V… 600V, 208V… 690V
Rated control supply voltage : 100… 250V AC, 50/60 Hz
Frame sizes : A, B, C, D, E, F
Electrical sizes : 19
Communication protocols : Modbus RTU, Profibus, Profinet, Ethercat, BACnet, Ethernet, DeviceNet, Anybus
Certifications : CE, cULus, CCC, EAC, ANCE. C-tick, KC
Approvals : ABS, DNV, Lloyd’s register, CCS, PRS, Class NKFeatures :
- Coated circuit boards for added protectoopm
- Detachable keypad rated IP66
- Graphical display with 17 languages
- Built-in Modbus RTU for monitoring/ control
Categories: ABB, Motor Protection & Controls -
S200
DESCRIPTION
A range designed to ensure efficiency and protection
The S200 range is designed to protect installations from overloads and short circuits, ensuring reliability and safety under all operating conditions. We feature a broad portfolio that offers solutions for many different applications, either for domestic, small commercial or industrial solutions. Due to approvals according to most major standards it can be used in installations worldwide. Furthermore the S200 range is fully compatible with a wide range of accessoriesTechnical Specs :
- 2A-100A
- 1P,2P,3P
- AC/DC Input Voltage
- IEC 60847-2, IEC 60898
Main Benefits :
- Versatile – wide range suitable for a variety of applications & segments.
- Global availability thanks to standards & approvals.
- Expandability through a wide range of accessories.
Main Features :
- Twin terminal for separate feeding of busbar and conductor.
- IP20 – finger safety.
- Easy identification of the product and highly resistant laser marking.
- Safe your time – all important data available right away.
- Quick identification thanks to laser printed EAN marking.
- Contact position indication.
- Captive screws – don’t lose what’s important for you.
- Whatever your application need is applicable with a wide range of accessories.
Categories: ABB, Circuit Protection & Motor Controls