ABB Motor Starter
Manual motor starters, also known as motor protection circuit breakers (MPCBs) or manual motor protectors (MMPs), are electromechanical protection devices for the main circuit. They are mainly used to switch motors ON/OFF manually and to provide fuseless protection against short-circuit, overload and phase failures. Fuseless protection saves costs, space and ensures a quick reaction under short-circuit condition by switching the motor off within milliseconds. Starter combinations are setup together with contactors and are available with screw or Push-in Spring terminals.
Related products
-
ABB Air Circuit Breaker (ACB)
Technical Specs
- IEC 60947-2
- 800A to 6300A
- Fixed Withdrawable
- 3P,4P
- 800A- 6300A
- Up to 150kA Icu @415V
Performance
Four sizes available, ensuring high performances in compact dimensions. Triple marking certification (IEC, UL, CCC).
Control
The All-In-One innovation able to manage any conditions of the grid thanks to advanced functions such as Load Shedding, Power Controller, ATS, Interface Protection, Synchrocheck logics, Adaptive Protection.
Connectivity
Perfect integration into all automation and energy management systems thanks to the eight communication protocols supported. Easy connection to the cloud computing platform ABB AbilityTM Electrical Distribution Control System. Remote connection through the embedded Bluetooth Low Energy technology.
Ease of use
Easy and safe operations and maintenance. Plug & play accessorizing. User friendly commissioning tools. Platform able to evolve during the lifecycle through the ABB Ability MarketplaceTM offering.
FEATURES
Distinctive features Reduction of energy costs with minimum impact. The loads are disconnected from the power supply for short periods, in the minimum number necessary and in a fixed order of priority, enabling power consumption peaks to be limited. This allows the contract drawn up with the energy provider to be renegotiated, reducing the power allocated, with a consequent reduction in total energy costs. Power limited only when necessary. Ekip Power Controller manages up to four different time bands: it is therefore possible to respect a particular power limit according to whether it is during the day (peak) or night (off peak). In this way, consumption during the day when rates are at their highest can be limited. Simple to install. Ekip Power Controller allows the installation to be managed efficiently with a simple architecture. Thanks to a patented design, it is sufficient to measure the total power of the installation without having to measure the power consumed by each load. Installation costs and times are thereby reduced to a minimum. Ready to use. Ekip Power Controller does not require the writing, implementation and testing of complicated programmes for PLC or computer because the logic has already been implemented in the protection unit and is ready to use; it is sufficient to set the installation parameters from a smartphone or directly from the circuit-breaker display. Improvement of the efficiency of the electrical system. Ekip Power Controller significantly helps to flatten the load curve, limiting the use of peaking power plants in favour of base load power plants with greater efficiency
Categories: ABB, Circuit Protection & Motor Controls -
ABB OPR
During a storm, when propagation field conditions are favorable, an OPR ESE air terminal will generate an upward leader. This upward leader from the OPR tip propagates towards the downward leader from the cloud.
The emission of an early streamer to a lightning event delivers a beneficial triggering time compared to a single rod air terminal exposed to the same conditions. This in turn drives the enhanced performance and protective distance achievable by ESE devices.
The beneficial triggering time is determined as the average time gained at the moment of sparkover, with efficiency confirmed by high-voltage laboratory testing. All ESE tests are defined in Annex C of the French standard NF C 17-102 (2011 Version).
This beneficial triggering makes OPR air terminals especially effective for the protection of industrial sites, administrative or public buildings, monuments and open-air sites such as sports grounds.Categories: ABB, Lightning Protection -
ABB MCB
Miniature circuit breakers (MCBs) ensure electrical safety in homes, offices and other buildings as well as for industrial applications by protecting electrical installations against overloads and short circuits. Once a fault is detected, the miniature circuit breaker automatically switches off the electrical circuit to prevent damage to wires and to avoid the risk of fire. Warranting reliability and safety for people and assets, MCBs are equipped with two tripping mechanisms: the delayed thermal tripping mechanism for overload protection and the magnetic tripping mechanism for short circuit protection.
System pro M compact®
With System pro M compact® ABB offers an extra-wide and complete range of miniature circuit breakers to cover most applications and markets. Our products are compliant to worldwide product standards (IEC, UL, CSA). With over 90 years of experience of innovation in the electrical sector, we offer established and certified quality.
Compliant to worldwide product standards (IEC, UL, CSA)
Characteristics: B, C, D, K, Z
Configurations: 1P, 1P+N, 2P, 3P, 3P+N, 4P
Breaking capacities up to 25 kA
Rated currents up to 100 AWide range
Extra-wide and complete range of MCBs to cover most applications and markets
Certified quality
Compliance to worldwide product standards (IEC, UL, CSA
Compact
Space and time saving thanks to the unique bottom-fixing auxiliary contactCategories: ABB, Circuit Protection & Motor Controls -
ABB Sace Formula
DESCRIPTION
Formula Al
- 15A-125A, lP – 3P, 230/440VAC
Formula A2
- 125A- 240A, 2P – 3~ 230/480VAC
Formula A3
- 320A- 630A, 3P, 230/480VAC
TmaxSeries
- 250A-1600A, 3P, 690VAC
Benefits
The SACE FORMULA circuit-breakers from 15A to 630A consist of the interruption part together
with the trip unit and they can be installed:- directly on the back plate of the cubicles.
- on a DIN rail (A1 and A2).
- back door (A1, A2 and A3, 2-3 4 poles).
ABB’s SACE® FORMULA™ molded case circuit breaker line offers simplicity and quality in some of the smallest dimensions available.
Technical Specs
IEC 60947-2
- fixed version;
- polarity: 1 pole (A1 and A2), 2 poles (A1 and A2), 3 poles (A1, A2 and A3), 4 poles (A1, A2 and A3);
- maximum breaking capacity of 36kA for A1 and A2 and of 50kA for A3 at 415V AC;
- fixed thermomagnetic trip unit (TMF) for protection of networks in alternating and direct current (A1, A2, A3);
- ELT LI electronic trip unit with fixed thresholds for the protection of networks in alternating current (A3);
- only two depths: 60mm (A1, A2) and 103.5mm (A3);
- standard front terminals;
- the possibility of use at 50°C without derating up to 250A (except for A1 125A);
- a special version for A3 300A-400A for use at 50°C.”
Features
- Ready to use
- Fixed thresholds on trip units, pre-cabled version of accessories and FORMULA link save time putting FORMULA in service.
- Easy to order and to use
- 1,2,3, and 4 poles versions up to 250A, no derating up to 50°C and common range of click-in accessories
- Compact and competitive
- Extremely compact dimensions and coordinated depths mean standardized dimensions and savings in distribution board design.
Certifications
SACE FORMULA DSA circuit-breakers and accessories are designed, manufactured and tested in conformity with:
- IEC 60947-2 standard;
- EC “Low Voltage Directive” (LVD) N° 2006/95/EC
- EC “Electromagnetic Compatibility Directive” (EMC) 2004/108/CE
Standards:
- ISO 9001 international Standard;
- EN ISO 9001 (equivalent) European Standards;
- UNI EN ISO 9001 (equivalent) Italian Standards;
- IRIS International Railway Industry Standard.
ABB Quality System obtained its first certification with RINA certification body in 1990.
Attention to protection of the environment is a priority for ABB. Confirmation of this is an Environmental Management System certified by RINA in conformity with the InternationalISO14001 Standard. In 1999, the Environmental Management System was integrated with the Occupational Health and Safety Management System according to the OHSAS 18001 Standard and later, in 2005, with the SA 8000 (Social Accountability 8000) Standard, committing itself to respect of business ethics and working conditions.
Categories: ABB, Circuit Protection & Motor Controls
Reviews