PRISMA

Search
Close this search box.
Established in 1994, Prisma Electrical Controls Corp. works closely with electrical engineers, designers and consultants for commercial, residential and industrial projects. Our team consists of dedicated and hardworking professionals who provide safe, reliable, energy-efficient, and cost-effective solutions

Where to Find Us

Search
Close this search box.
Established in 1994, Prisma Electrical Controls Corp. works closely with electrical engineers, designers and consultants for commercial, residential and industrial projects. Our team consists of dedicated and hardworking professionals who provide safe, reliable, energy-efficient, and cost-effective solutions

Where to Find Us

ABB

Showing all 16 results

  • ABB OPR

    DESCRIPTION

    During a storm, when propagation field conditions are favorable, an OPR ESE air terminal will generate an upward leader. This upward leader from the OPR tip propagates towards the downward leader from the cloud.

    The emission of an early streamer to a lightning event delivers a beneficial triggering time compared to a single rod air terminal exposed to the same conditions. This in turn drives the enhanced performance and protective distance achievable by ESE devices.
    The beneficial triggering time is determined as the average time gained at the moment of sparkover, with efficiency confirmed by high-voltage laboratory testing. All ESE tests are defined in Annex C of the French standard NF C 17-102 (2011 Version).

    This beneficial triggering makes OPR air terminals especially effective for the protection of industrial sites, administrative or public buildings, monuments and open-air sites such as sports grounds.

     

    OPR: the high pulse voltage, early streamer lightning air terminal

    In ongoing collaboration with the CNRS (French National Research Organization), ABB continues to innovate and has developed a new generation of lightning protection devices – the OPR early streamer emission (ESE system). This OPR range delivers improved performance in early streamer initiation and propagation, and represents further progress in terms of lightning protection, operating autonomy and ease of maintenance. These advancements reinforce ABB’s leading position in active lightning protection, with over 200000 installations worldwide.

    Categories: ,
  • Air Circuit Breaker (ACB)

    Technical Specs

    • IEC 60947-2
    • 800A to 6300A
    • Fixed Withdrawable
    • 3P,4P
    • 800A- 6300A
    • Up to 150kA Icu @415V

     

    Performance

    Four sizes available, ensuring high performances in compact dimensions. Triple marking certification (IEC, UL, CCC).

     

    Control

    The All-In-One innovation able to manage any conditions of the grid thanks to advanced functions such as Load Shedding, Power Controller, ATS, Interface Protection, Synchrocheck logics, Adaptive Protection.

     

    Connectivity

    Perfect integration into all automation and energy management systems thanks to the eight communication protocols supported. Easy connection to the cloud computing platform ABB AbilityTM Electrical Distribution Control System. Remote connection through the embedded Bluetooth Low Energy technology.

     

    Ease of use

    Easy and safe operations and maintenance. Plug & play accessorizing. User friendly commissioning tools. Platform able to evolve during the lifecycle through the ABB Ability MarketplaceTM offering.

     

    FEATURES

    Distinctive features Reduction of energy costs with minimum impact. The loads are disconnected from the power supply for short periods, in the minimum number necessary and in a fixed order of priority, enabling power consumption peaks to be limited. This allows the contract drawn up with the energy provider to be renegotiated, reducing the power allocated, with a consequent reduction in total energy costs. Power limited only when necessary. Ekip Power Controller manages up to four different time bands: it is therefore possible to respect a particular power limit according to whether it is during the day (peak) or night (off peak). In this way, consumption during the day when rates are at their highest can be limited. Simple to install. Ekip Power Controller allows the installation to be managed efficiently with a simple architecture. Thanks to a patented design, it is sufficient to measure the total power of the installation without having to measure the power consumed by each load. Installation costs and times are thereby reduced to a minimum. Ready to use. Ekip Power Controller does not require the writing, implementation and testing of complicated programmes for PLC or computer because the logic has already been implemented in the protection unit and is ready to use; it is sufficient to set the installation parameters from a smartphone or directly from the circuit-breaker display. Improvement of the efficiency of the electrical system. Ekip Power Controller significantly helps to flatten the load curve, limiting the use of peaking power plants in favour of base load power plants with greater efficiency

  • CA5-40E Auxiliary Contact Block

    DESCRIPTION

    CA5-40E is a 4-pole front mounted auxiliary contact block equipped with screw terminals. CA5-..E version offers terminal assortment matching the marking of 3-pole A serie contactors: A..-30-00, A..-40-00, A..-22-00. CA5-40E is available with 4 N.O. and 0 N.C. instantaneous contacts for standard industrial environments.

     

    Dimensions

    Product Net Width : 43 mm
    Product Net Depth / Length : 39 mm
    Product Net Height : 47 mm
    Product Net Weight : 0.06 kg

     

    Technical

    Number of Auxiliary Contacts NO : 4
    Number of Auxiliary Contacts NC : 0
    Rated Operational Voltage : Auxiliary Circuit 690 V
    Rated Frequency (f) : Auxiliary Circuit 50 / 60 Hz

     

  • Contactor

    DESCRIPTION

    • 9A – 370A, 3P, 240-690V
    • 1 NO, 230-240V
    • 1N0-1NC, 230-240V
    • IEC 60947-4-1

    Contactors and contactor relays
    To keep things running you need control

    “Contactor relays for auxiliary circuit switching
    ABB’s contactor relays offering features products of technological advancement as well as products with specific purposes. NF contactor relays allow use in all parts of the world and in all network conditions. The mini contactor relays range offer various contact combinations and specific connection possibilities. The AS contactor relays are efficient and allow you to optimize your equipment design.”

  • Miniature Circuit Breaker (MCB)

    DESCRIPTION

    Miniature circuit breakers (MCBs) ensure electrical safety in homes, offices and other buildings as well as for industrial applications by protecting electrical installations against overloads and short circuits. Once a fault is detected, the miniature circuit breaker automatically switches off the electrical circuit to prevent damage to wires and to avoid the risk of fire. Warranting reliability and safety for people and assets, MCBs are equipped with two tripping mechanisms: the delayed thermal tripping mechanism for overload protection and the magnetic tripping mechanism for short circuit protection.

    System pro M compact®
    With System pro M compact® ABB offers an extra-wide and complete range of miniature circuit breakers to cover most applications and markets. Our products are compliant to worldwide product standards (IEC, UL, CSA). With over 90 years of experience of innovation in the electrical sector, we offer established and certified quality.

    • Compliant to worldwide product standards (IEC, UL, CSA)
    • Characteristics: B, C, D, K, Z
    • Configurations: 1P, 1P+N, 2P, 3P, 3P+N, 4P
    • Breaking capacities up to 25 kA
    • Rated currents up to 100 A

     

    Benefits and Features :

    Wide range
    Extra-wide and complete range of MCBs to cover most applications and markets.

    Certified quality
    Compliance to worldwide product standards (IEC, UL, CSA).

    Compact
    Space and time saving thanks to the unique bottom-fixing auxiliary contact.

  • Moulded Case Circuit Breaker (MCCB)

    DESCRIPTION

    The new SACE FORMULA family consists of three new A1,  A2 and A3 frames which reach up to 125A, 250A and 630A respectively. The three frames are available in the fixed version, with front terminals. The protection trip unit has fixed thermal and magnetic threshold values for putting the circuit-breaker into service more rapidly. This way selection becomes simple and precise. With a few sales codes which simplify selection and make ordering easier. Installation is simplified, and thanks to easy and rapid fixing operations and set-up, the circuit-breaker is
    ready for use immediately

    Quality is great versatility. In addiction to proposing all three frames in the three-pole and four-pole version, for the first time ABB SACE now proposes single-pole and two-pole versions up
    to 250A, opening the door to the most varied application fields. Quality is compact overall dimensions. The SACE FORMULA A1 and A2 depth of just 60 mm is the lowest on the market up
    to 250A. Turn on screen reader support

     

  • NF Contactor Relays

    DESCRIPTION

    Secure uptime and optimize stocks with AF latest technology

    NF contactor relays are featuring AF technology as standard. The electronically controlled coil offers multiple benefits over conventional alternatives, and together with ABB’s wide product offering, an optimal configuration, every time.

     

    Main Benefits

    • Optimize logistics  and cut administration costs with fewer product variants to handle
    • Access global support and use the same products in all parts of the world
    • A reduction of the coil’s energy consumption by 80% lets you save energy
    • Secure your uptime by letting the AF technology overbridge voltage drops and sags.

     

    Main Features

    • 4 and 8-pole ranges available, 8-poles with permanently fixed 4-pole auxiliary contact block
    • Screw, spring and ring tongue connection types available
    • Built-in surge suppression
    • Overlapping of lagging / leading contacts for NF33/11 and NF51/11 variants
    • Easy-to-use accessories through snap-to-connect function
    • Mechanically linked contacts.
  • NS Contactor Relays

    DESCRIPTION

    Efficient and space saving
    NS compact contactor relays allow you to optimize equipment design and provides reliable, time and cost saving solutions.

     

    Main Benefits

    • Right performances at the right price
    • Same dimensions in depth, width and height throughout the range in AC or DC control and for screw and spring terminals
    • Easy, fast and secure assembly of accessories.

     

    Main Features

    • Complete offer of 4 and 8-pole with various contact combinations
    • Screw and spring connection types available
    • Direct control by PLC removing any use of interface relay and reducing panel power consumption
    • Side clipped-on surge suppressors, integrated into overall contactor dimensions
    • Mirror and mechanically linked contacts.
  • PSTX Soft Starter

    DESCRIPTION

    The PSTX combines many years of research and product development with extensive knowledge of application specific requirements and needs. The PSTX is our latest advancement in motor control and protection and adds new functionality with increased reliability to any motor starting application.

     

    Benefits :

    Complete Motor Protection

    The PSTX offers complete motor protection and is able to handle both load and network irregularities. PT-100, earth fault protection and over/under voltage protection along with many other functions keep your motor safer than ever.

    Reliable Operations

    Time to use your processes to their full potential. The PSTX features many application enhancing features, including torque control, standstill brake, dynamic brake, motor heating, pump cleaning, underload, and lock rotor protections.

    Flexible Communication

    Bulit-in Modbus and as an option Anybus for all major communication protocols such as Modbus RTU, Profibus, Profinet, Ethercat, BACnet, Ethernet and DeviceNet.

     

    Technical information :

    Current : 30A… 1250A (inside-delta: 2160A)
    Main voltage : 208V… 600V, 208V… 690V
    Rated control supply voltage : 100… 250V AC, 50/60 Hz
    Frame sizes : A, B, C, D, E, F
    Electrical sizes : 19
    Communication protocols : Modbus RTU, Profibus, Profinet, Ethercat, BACnet, Ethernet, DeviceNet, Anybus
    Certifications : CE, cULus, CCC, EAC, ANCE. C-tick, KC
    Approvals : ABS, DNV, Lloyd’s register, CCS, PRS, Class NK

     

    Features :

    • Coated circuit boards for added protectoopm
    • Detachable keypad rated IP66
    • Graphical display with 17 languages
    • Built-in Modbus RTU for monitoring/ control
  • RCBO

    DESCRIPTION

    RCBOs combine, in a single device, the protection against leakage current to ground typical of RCCBs with the protection against over currents (overload and short-circuit) typical of MCBs.

    • RCBOs are a compact solution for the protection of people and connected equipment.
    • DS201 Series
    • 16A- 40A, lP+N, 240VAC, 30mA
  • RCBO DS201

    DESCRIPTION

    DS201 RCBOs offer protection of end user single-phase circuits against overload and short-circuit currents protection against the effects of sinusoidal alternating and direct pulsating earth fault currents as well as protection against indirect contact and additional protection against direct contact.

    Easy to install
    Easier and faster wiring operations thanks to the two slots of different dimensions that allow connection both with cable and busbars.

    Continuous operation
    Reduced downtime for maintenance operations thanks to the earth fault indicator. Fast and easy identification of the contacts’ status thanks to the CPI window.

    Expandability
    Wide range of accessories with lots of different functions offered

    Technical Specs:

    • AC, A, G, AP-R, F type available
    • IEC/EN 61009
    • 1P+N
    • Breaking capacity of 4.5, 6, 10 kA
    • Sensitivity from 10 to 300 mA
    • B, C, D and K tripping characteristic
    • Test pushbutton to verify the correct functioning of the device
    • Earth fault indicator to identify easier earth faults
    • Information on the device are laser printed to make them clearly visible and long lasting
    • Contact position indicator (CPI): to always know the status of the contacts (red: closed contacts; green: open contacts) independently on the toggle position
  • S200

    DESCRIPTION

    A range designed to ensure efficiency and protection
    The S200 range is designed to protect installations from overloads and short circuits, ensuring reliability and safety under all operating conditions. We feature a broad portfolio that offers solutions for many different applications, either for domestic, small commercial or industrial solutions. Due to approvals according to most major standards it can be used in installations worldwide. Furthermore the S200 range is fully compatible with a wide range of accessories

     

    Technical Specs :

    • 2A-100A
    • 1P,2P,3P
    • AC/DC Input Voltage
    • IEC 60847-2, IEC 60898

     

    Main Benefits :

    • Versatile – wide range suitable for a variety of applications & segments.
    • Global availability thanks to standards & approvals.
    • Expandability through a wide range of accessories.

     

    Main Features :

    • Twin terminal for separate feeding of busbar and conductor.
    • IP20 – finger safety.
    • Easy identification of the product and highly resistant laser marking.
    • Safe your time – all important data available right away.
    • Quick identification thanks to laser printed EAN marking.
    • Contact position indication.
    • Captive screws – don’t lose what’s important for you.
    • Whatever your application need is applicable with a wide range of accessories.
  • Sace Formula

    DESCRIPTION

    Formula Al

    • 15A-125A, lP – 3P, 230/440VAC

    Formula A2

    • 125A- 240A, 2P – 3~ 230/480VAC

    Formula A3

    • 320A- 630A, 3P, 230/480VAC

    TmaxSeries

    • 250A-1600A, 3P, 690VAC

     

    Benefits

    The SACE FORMULA circuit-breakers from 15A to 630A consist of the interruption part together
    with the trip unit and they can be installed:

    • directly on the back plate of the cubicles.
    • on a DIN rail (A1 and A2).
    • back door (A1, A2 and A3, 2-3 4 poles).

    ABB’s SACE® FORMULA™ molded case circuit breaker line offers simplicity and quality in some of the smallest dimensions available.

     

    Technical Specs

    IEC 60947-2

    • fixed version;
    • polarity: 1 pole (A1 and A2), 2 poles (A1 and A2), 3 poles (A1, A2 and A3), 4 poles (A1, A2 and A3);
    • maximum breaking capacity of 36kA for A1 and A2 and of 50kA for A3 at 415V AC;
    • fixed thermomagnetic trip unit (TMF) for protection of networks in alternating and direct current (A1, A2, A3);
    • ELT LI electronic trip unit with fixed thresholds for the protection of networks in alternating current (A3);
    • only two depths: 60mm (A1, A2) and 103.5mm (A3);
    • standard front terminals;
    • the possibility of use at 50°C without derating up to 250A (except for A1 125A);
    • a special version for A3 300A-400A for use at 50°C.”

     

    Features

    • Ready to use
    • Fixed thresholds on trip units, pre-cabled version of accessories and FORMULA link save time putting FORMULA in service.
    • Easy to order and to use
    • 1,2,3, and 4 poles versions up to 250A, no derating up to 50°C and common range of click-in accessories
    • Compact and competitive
    • Extremely compact dimensions and coordinated depths mean standardized dimensions and savings in distribution board design.

     

    Certifications

    SACE FORMULA DSA circuit-breakers and accessories are designed, manufactured and tested in conformity with:

    • IEC 60947-2 standard;
    • EC “Low Voltage Directive” (LVD) N° 2006/95/EC
    • EC “Electromagnetic Compatibility Directive” (EMC) 2004/108/CE

     

    Standards:

    • ISO 9001 international Standard;
    • EN ISO 9001 (equivalent) European Standards;
    • UNI EN ISO 9001 (equivalent) Italian Standards;
    • IRIS International Railway Industry Standard.

     

    ABB Quality System obtained its first certification with RINA certification body in 1990.
    Attention to protection of the environment is a priority for ABB. Confirmation of this is an Environmental Management System certified by RINA in conformity with the International

    ISO14001 Standard. In 1999, the Environmental Management System was integrated with the Occupational Health and Safety Management System according to the OHSAS 18001 Standard and later, in 2005, with the SA 8000 (Social Accountability 8000) Standard, committing itself to respect of business ethics and working conditions.

  • SACE Tmax XT

    DESCRIPTION

    The SACE Tmax XT series of Moulded Case Circuit Breakers (MCCBs) are designed to maximize ease of use, integration and connectivity while reliably delivering safety and quality. Rather than just offering standalone protection, they are seen as key elements of the system that give you complete flexibility, extreme breaking capabilities and reliable performance under pressure. With seven different sizes and protection features of up to 1600A there’s a solution for every purpose.

    Tmax XT moulded case circuit breakers guarantee an extremely high performance level while being progressively smaller in size, simple to install and able to provide increasingly better safety. Range is complete with four frame sizes: XT1, XT2 up to 160A and XT3, XT4 up to 250A.

     

    FEATURES

    • High breaking capacity in compact dimensions
    • XTraordinary limiting characteristics allow savings in copper and footprint in switchboard, high selectivity values and very compact motor protection solutions.
    • Ease of use and installation flexibility
    • A dedicated range of accessories and a renewed solution for electronic trip units to adapt Tmax XT to different applications scenarios.
    • Customized protection and information availability
    • Specific electronic trip units for energy metering, motor protection and generator protection in addition to a Modbus communication module for integration in a supervision system.
    • Increased safety for operators
    • Wide range of keylocks and padlocking options, plug in and withdrawable versions to speed up maintenance operations and improved diagnostic to have ready to use information about breakers’ status.

     

    Benefits

    Cloud connected
    To keep a system under control it should be monitorable from everywhere.

    Plant management of the future – SACE Tmax XT sets standards in modern plant and energy management. Access, monitor and control information remotely, anywhere, at any time. Improving efficiency and saving energy.

    Tailor made
    Even if the task is complex the solution is simple.

    Maximum flexibility for every application – SACE Tmax XT sets standards for electrical installations. Easy selection, one-fits-all accessories and intuitive design pave the way for smart manufacturing of panels and fast upgrades. Even for the most critical projects.

    Outstanding technology
    Meeting high-performance requirements with zero efforts.

    Continuity of service and equipment protection – SACE Tmax XT sets standards when extreme breaking capacity is needed. Sharing the same logics, interfaces and features regardless of operating voltage and environmental conditions. Embedding the most advanced protection into the smallest of frames.

    Top-level products
    The reliability of a system relies on the interplay of details.

    Absolute attention to detail, with style – from design to manufacturing, SACE Tmax XT sets standards for edge technologies. Almost a century of research and experience means top-level products that are ready to face future challenges.

     

    Technical Specs

    • IEC 60947-2
    • 16A to 1600A
    • 3P,4P
    • Fixed, withdrawable
    • Upto to 200kA Icu @415V
  • SH200

    DESCRIPTION

    Miniature circuitbreakers SH 200. The details make the difference A range designed to ensure efficiency and protection
    The SH 200 miniature circuit breaker is perfectly suitable for protecting lighting and power socket circuits that can be frequently found in residential areas. ABB used its years of experience with miniature circuit breaker to create this product by combining the optimum features for residential use alone.

     

    Features :

    “The Compact Home range is versatile to provide the customer with the perfect solution for residential over current protection. It is available in tripping characteristics B and C type; with breaking capacities between 3 and 6 kA. As usual for ABB miniature circuit breaker, SH 200 is available from one to four poles and additional in one &
    three pole plus Neutral. The rated currents are limited to 6 A up to 40 A as it is common in residential applications.”

     

    Technical Specs :

    • 6A-63A
    • 1P,2P,3P
    • IEC 60898

     

    Benefits :

    • Extra-wide and complete range of MCBs to cover most applications and markets.
    • Meeting worldwide standards.
    • Certificates, documentation, training or background information to support customers due to their daily work.
    • Space and time saving thanks to the unique bottom-fixing auxiliary contact.
  • Thermal Overload Relays (TOR)

    DESCRIPTION

    Motor protection for overload and phase failure

    Thermal overload relays are economic electromechanical protection devices for the main circuit. In combination with contactors, they provide reliable protection against overloads and phase failures for motors. They allow to set up customized motor starting solutions according to individual needs.

     

    Main Benefits

    • Reliable protection for motors in the event of overload or phase failure
    • Easy creation of individual motor starting solutions
    • Perfect fit to ABB’s contactors: directly mounted and connected without further wiring
    • Single mounting kits and accessories for remote control available for specific applications
    • Selectable automatic reset mode allows to reduce downtimes and travelling costs
    • In combination with ABB mini contactors, the installation in narrow spaces is possible
    • Rated for AC and DC loads

     

    Main Features

    • Trip class 10/10A
    • Adjustable current setting ranges
    • Overload protection with phase loss sensitivity
    • Temperature compensation up to +70°C
    • Selection between automatic or manual reset mode
    • Stop and test function
    • Finger safe housing (IP20)
    • Large markings on setting scale for precise setting
    • Suitable for 1-phase applications
    Category: