ABB – RCBO
RCBOs combine, in a single device, the protection against leakage current to ground typical of RCCBs with the protection against over currents (overload and short-circuit) typical of MCBs.
RCBOs are a compact solution for the protection of people and connected equipment.
DS201 Series
16A- 40A, lP+N, 240VAC, 30mA
Related products
-
ABB – TMAX XT
The SACE Tmax XT series of Moulded Case Circuit Breakers (MCCBs) are designed to maximize ease of use, integration and connectivity while reliably delivering safety and quality. Rather than just offering standalone protection, they are seen as key elements of the system that give you complete flexibility, extreme breaking capabilities and reliable performance under pressure. With seven different sizes and protection features of up to 1600A there’s a solution for every purpose.
Tmax XT moulded case circuit breakers guarantee an extremely high performance level while being progressively smaller in size, simple to install and able to provide increasingly better safety. Range is complete with four frame sizes: XT1, XT2 up to 160A and XT3, XT4 up to 250A.Category: ABB -
Sace Formula
DESCRIPTION
Formula Al
- 15A-125A, lP – 3P, 230/440VAC
Formula A2
- 125A- 240A, 2P – 3~ 230/480VAC
Formula A3
- 320A- 630A, 3P, 230/480VAC
TmaxSeries
- 250A-1600A, 3P, 690VAC
Benefits
The SACE FORMULA circuit-breakers from 15A to 630A consist of the interruption part together
with the trip unit and they can be installed:- directly on the back plate of the cubicles.
- on a DIN rail (A1 and A2).
- back door (A1, A2 and A3, 2-3 4 poles).
ABB’s SACE® FORMULA™ molded case circuit breaker line offers simplicity and quality in some of the smallest dimensions available.
Technical Specs
IEC 60947-2
- fixed version;
- polarity: 1 pole (A1 and A2), 2 poles (A1 and A2), 3 poles (A1, A2 and A3), 4 poles (A1, A2 and A3);
- maximum breaking capacity of 36kA for A1 and A2 and of 50kA for A3 at 415V AC;
- fixed thermomagnetic trip unit (TMF) for protection of networks in alternating and direct current (A1, A2, A3);
- ELT LI electronic trip unit with fixed thresholds for the protection of networks in alternating current (A3);
- only two depths: 60mm (A1, A2) and 103.5mm (A3);
- standard front terminals;
- the possibility of use at 50°C without derating up to 250A (except for A1 125A);
- a special version for A3 300A-400A for use at 50°C.”
Features
- Ready to use
- Fixed thresholds on trip units, pre-cabled version of accessories and FORMULA link save time putting FORMULA in service.
- Easy to order and to use
- 1,2,3, and 4 poles versions up to 250A, no derating up to 50°C and common range of click-in accessories
- Compact and competitive
- Extremely compact dimensions and coordinated depths mean standardized dimensions and savings in distribution board design.
Certifications
SACE FORMULA DSA circuit-breakers and accessories are designed, manufactured and tested in conformity with:
- IEC 60947-2 standard;
- EC “Low Voltage Directive” (LVD) N° 2006/95/EC
- EC “Electromagnetic Compatibility Directive” (EMC) 2004/108/CE
Standards:
- ISO 9001 international Standard;
- EN ISO 9001 (equivalent) European Standards;
- UNI EN ISO 9001 (equivalent) Italian Standards;
- IRIS International Railway Industry Standard.
ABB Quality System obtained its first certification with RINA certification body in 1990.
Attention to protection of the environment is a priority for ABB. Confirmation of this is an Environmental Management System certified by RINA in conformity with the InternationalISO14001 Standard. In 1999, the Environmental Management System was integrated with the Occupational Health and Safety Management System according to the OHSAS 18001 Standard and later, in 2005, with the SA 8000 (Social Accountability 8000) Standard, committing itself to respect of business ethics and working conditions.
Categories: ABB, Circuit Protection & Motor Controls -
ABB – MCCB
“The new SACE FORMULA family consists of three new A1,
A2 and A3 frames which reach up to 125A, 250A and 630A
respectively.
The three frames are available in the fixed version, with front
terminals.
The protection trip unit has fixed thermal and magnetic
threshold values for putting the circuit-breaker into service
more rapidly. This way selection becomes simple and precise.
With a few sales codes which simplify selection and make
ordering easier. Installation is simplified, and thanks to easy
and rapid fixing operations and set-up, the circuit-breaker is
ready for use immediately”“Quality is great versatility. In addiction to proposing all three
frames in the three-pole and four-pole version, for the first time
ABB SACE now proposes single-pole and two-pole versions up
to 250A, opening the door to the most varied application fields.
Quality is compact overall dimensions. The SACE FORMULA
A1 and A2 depth of just 60 mm is the lowest on the market up
to 250A. “Category: ABB -
ABB – S200
The S200 range is designed to protect installations from overloads and short circuits, ensuring reliability and safety under all operating conditions. We feature a broad portfolio that offers solutions for many different applications, either for domestic, small commercial or industrial solutions. Due to approvals according to most major standards it can be used in installations worldwide. Furthermore the S200 range is fully compatible with a wide range of accessories
2A-100A
1P,2P,3P
AC/DC Input Voltage
IEC 60847-2, IEC 60898Category: ABB
Reviews
There are no reviews yet.